Dc-Motors Error (Feed Rollers); Error With Carriage - Pfaff 8390 Instruction Manual

Table of Contents

Advertisement

Adjustment
13
DC-motors error
.12.03
13

Error with carriage

.12.04
104
(Feed rollers)
Error number
Discription
0
No error
10
Incorrect command code
11
Invalid speed
12
Invalid acceleration
13
Start with dead motor
14
Set differential with master
15
Contouring error
16
Overload current
17
Over 5 V positioning voltage with standing motor (possible cause:
Load moment (tension, surge, stationary rollers, if necessary too
large differential tolerance)
Error number
Discription
0
No error
1
Transmission error
2
Data error
3
Parameter error
4
ETX missing
5
Watchdog
6
Timeout
7
ACK missing
8
Checksum
9
Error P40ED with error number
10
Safety monitoring