Adjustment
12
Clearance between the hot air nozzle and the feed rollers
.04
Requirement
There should be a clearance of 1 – 2 mm between the hot air nozzle 3 and the top feed
roller 4.
2
1
4
3
Fig. 12 - 02
Turn adjustment screw 1 (screw 2) in accordance with the requirement.
12 - 3