4.25 Adjusting the Distance Between the Pens

This function compensates for the difference in position between the cutter pen and the plotter pen. First of
all, mount a plotter pen in the pen station and draw a cross. Next, mount a cutter pen in the cutter pen holder
and cut a second cross (the reference cross). The difference between the two crosses can be adjusted by
inputting corrective values. The setting range is within -3.0 mm to +3.0 mm, in 0.1 mm intervals.
(1) Press the
C L E A R B U F F E R
(2) Press the
F E E D & C U T
B L A D E W A R E S E T U P
P E N U P / D O W N
(3) Press the
C U T L I N E P A T .
T A N G E N T I A L
I N I T . B
(4) Press the
P E N U P S P E E D
I N I T I A L F E E D
A U T O P R E F E E D
(5) Press the
A D V A N C E D F U N C .
S E T U P M E N U
T E S T
(6) After the crosses have been drawn, the display changes to the following.
(7) Press the
(PAUSE) key to switch to PAUSE mode.
(NEXT) or
A D V A N C E D F U N C .
(ENTER) key, and then press the
until the following menu is displayed.
P E N 1 / 2 A D J .
(ENTER) key, and then wait for the Pen Compensation Pattern
Prompt.
P L O T A D J P A T .
,
,
, and
drawing start position, and then press the
pattern.
The cross cut by the cutter pen
in the cutter pen holder. (the reference cross)
Compensation
value Y
Compensation value X
X = 0 . 0
Y = 0 . 0
Using the cross that was cut by the cutter pen mounted in the cutter pen holder as
the reference cross, input the values corresponding to the difference between the
reference cross and the first cross that was drawn. (In the drawing above, for
example, the difference is in the -X and +Y directions. In this case, input X = -
*mm, and Y = +*mm.)
Use the
or
keys to move the cursor to the items to be changed, and the
or
keys to select the select the values and then press the
key. To cancel the selection, press the
(PAUSE) key to cancel PAUSE mode.
CHECKPOINT
The setting is retained in the internal memory even when the power is turned off.
(PREV.) key until the following menu is displayed.
(POSITION) keys to move the pen to the pattern
(ENTER) key to start drawing the
The cross drawn
Y
by the pen
in the pen holder.
X
(NEXT) or
Function Settings and Operations
(NEXT)or
(PREV.) key
(ENTER)