Hose Routing for WIDE-OUT™ Blades
To DS Wing
Base (outside)
To DS Wing
Rod (inside)
To Lift Ram
To DS Angle Ram
To PS Angle Ram
To PS Wing
Rod (inside)
To PS Wing
Base (outside)
Lit. No. 49513, Rev. 00
MAINTENANCE
Do not raise blade during fi ll process as
this may cause pump cavitation.
11. For straight blades, any angle will do, but
MVP PLUS and WIDE-OUT blades must
be in the fully retracted (vee) position. With
the lift ram fully retracted, fi ll the reservoir
with WESTERN
Hydraulic Fluid to –40°F (–40°C), or other
fl uid conforming to Military Specifi cation
MIL-H-5606A, such as Mobil Aero HFA or
Shell AeroShell
NOTE: On MVP PLUS™ and WIDE-OUT™
blades, add fl uid only when all rams are
retracted.
AeroShell
®
94
CAUTION
High Performance
®
Fluid 4. Replace the fi ll plug.
®
is a registered (
®
) trademark of Shell Oil Company.