CHAPTER 3: Using the Local Terminal for Unit Setup and Management
3.6.1.6 P
-S
OWER
AVING
These counters apply only to Access Points.
• PS stations — Number of associated stations currently working in Power Save
mode.
• Internally Discarded — Number of frames that were discarded because of
aging.
• Table — Valid only when Power Save mode is enabled.
Station ID — Current number of buffered frames per station.
Aged — Number of buffered frames that were aged out from buffer per
station.
Send — Number of buffered frames that were sent to a specific station.
Queue — Number of frames that could not be stored in the buffer.
3.6.2 S
S
URVEY
OFTWARE
The Survey Software menu enables you to align antennas and to assess the radio
signal quality of a point-to-point link. The sub-menu includes the following
options:
• Operation Mode – When running a Site Survey, set the units on either side of
the link to either receive (option 1) or transmit (option 2) packets (one unit
should be set to transmit and the other to receive).
• Start Statistics – Type 2 and then press any digit to start Site Survey.
• Stop Statistics – Type 3 and then press any key to stop update of Site Survey
statistics.
3.6.3 U
S
SING THE
ITE
1. Roughly align the antennas on either side of the link before starting the Site
Survey procedure.
2. Verify that the Ethernet cables are disconnected from both units.
3. Type 1 to access the Operation mode screen. Set the units on either side of the
link to either receive (option 1) or transmit (option 2) packets (one unit should
be set to transmit and the other to receive).