Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
2.5

Removal of Reactor / Partition Plate

Procedure
Step
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
201
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Preparation
Reactor
„ Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
„ Remove the electrical box
according to the "Removal of
Electrical Box".
(R7224)
(R7225)
Partition plate
(R7226)
SiENBE04-808_A