INSTALLATION
MANUAL
R410A Split Series
Models
RXS50J2V1B
RXS60F3V1B
RXS50G2V1B RKS50G2V1B
RXS60F2V1B
RYN50E3V1B RN50E3V1B
RYN60E3V1B RN60E3V1B
RX50G2V1B
RX60G2V1B
RKS50J2V1B
RKS60F3V1B
RKS60F2V1B
ARXS50G2V1B
ARXS50E3V1B
Installationsanleitung
Split-Baureihe R410A
Manuel d'installation
Montagehandleiding
R410A Split-systeem
Manual de instalación
Manuale d'installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой

Installation manual

English
R410A Split series
Deutsch
Français
Série split R410A
Nederlands
Español
Serie Split R410A
Italiano
ΕλληνικÜ
Portugues
Série split R410A
Рóссêий
Montaj kýlavuzlarý
Türkçe
R410A Split serisi

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RXS50J2V1B

  • Page 1: Installation Manual

    English R410A Split series Installationsanleitung Deutsch Split-Baureihe R410A Manuel d’installation Français Série split R410A Montagehandleiding Models Nederlands R410A Split-systeem RXS50J2V1B RKS50J2V1B Manual de instalación RXS60F3V1B RKS60F3V1B Español Serie Split R410A RXS50G2V1B RKS50G2V1B Manuale d’installazione RXS60F2V1B RKS60F2V1B Italiano Serie Multiambienti R410A RYN50E3V1B RN50E3V1B Εγχειρßδιο...
  • Page 2 3SB64564-9D...
  • Page 3 3SB64564-14E...
  • Page 4: Safety Precautions

    Safety Precautions • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices WARNING ..Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION ..
  • Page 5: Precautions For Selecting The Location

    Accessories Accessories supplied with the outdoor unit: (A) Installation manual (B) Drain plug (Heat pump model) (C) Refrigerant charge label There is on the bottom packing case. (D) Multilingual fluorinated greenhouse gases label Precautions for Selecting the Location 1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified. 2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbours of the user.
  • Page 6: Outdoor Unit Installation Drawings

    Outdoor Unit Installation Drawings Max. allowable length Min. allowable length 1.5m Max. allowable height Additional refrigerant required for refrigerant 20g/m pipe exceeding 10m in length. Gas pipe O.D. 12.7mm Wrap the insulation pipe with the finishing Liquid pipe O.D. 6.4mm tape from bottom to top.
  • Page 7: Precautions On Installation

    Installation Guidelines • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow, follow the installation guidelines below. • For any of the below installation patterns, the wall height on the outlet side should be 1200mm or less. Wall facing one side Walls facing two sides More than 100...
  • Page 8: Flaring The Pipe End

    Outdoor Unit Installation Flaring the pipe end (Cut exactly at 1) Cut the pipe end with a pipe cutter. right angles.) Remove burrs. 2) Remove burrs with the cut surface facing Flaring downward so that the chips do not enter the pipe. Set exactly at the position shown below.
  • Page 9: Purging Air And Checking Gas Leakage

    Purging air and checking gas leakage • When piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING • Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle. •...
  • Page 10: Refrigerant Piping Work

    Outdoor Unit Installation Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410A Fill from the liquid pipe in liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation. 1) Before filling, check whether the cylinder has a siphon attached or not.
  • Page 11: Pump Down Operation

    Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap from liquid stop valve and gas stop valve. 2) Carry out forced cooling operation. Hexagonal wrench 3) After 5 to 10 minutes, close the liquid stop valve with a hexagonal wrench.
  • Page 12 Wiring WARNING • Do not use tapped wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire.
  • Page 13: Trial Operation And Testing

    CAUTION • When connecting the connection wires to the terminal board using a single core wire, be sure to perform curling. Problems with the work may cause heat and fires. Stripping wire at terminal block 3) Pull the wire and make sure that it does not disconnect. Then fix the wire in place with a wire stop. Trial Operation and Testing Trial operation and testing 1-1 Measure the supply voltage and make sure that it falls in the specified range.
  • Page 14 Two-dimensional bar code is a code for manufacturing. 3P254362-2C M09B391 (1101) HT...