Outdoor Unit
2.4

Removal of Reactor / Partition Plate

Procedure
Step
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
Remove the 2 screws.
1
166
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Reactor
Points
Preparation
Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
Remove the electrical box
according to the "Removal of
Electrical Box".
(R11879)
(R11880)
(R11881)