Removal Of Four Way Valve - Daikin FTXS20G2V1B Service Manual

G-series
Hide thumbs Also See for FTXS20G2V1B:
Table of Contents

Advertisement

SiENBE04-808_A
2.7

Removal of Four Way Valve

Procedure
Step
1
Pull out the electronic
expansion valve coil.
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the
compressor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Red (U)
Yellow (V)
Blue (W)
Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)
(R7235)