Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
4.3
Removal of PCB
Procedure
Step
1
Remove the screw and
remove the electrical
box cover.
2
Detach the insulation
sheet.
3
Remove the 2 screws
of the earth terminals.
245
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Electrical box cover
Preparation
Remove the panels
according to the "Removal of
Outer Panels".
Remove the electrical box
according to the "Removal of
Electrical Box".
(R12274)
(R8156)
The trimmed part goes front.
Insulation
sheet
Earth
terminals
(R8157)
(R8158)
SiENBE04-808_A
Points
Removal Procedure