SiENBE04-808_A
3.2

ARC433 Series

Check Method 1
1. When the timer cancel button is held down for 5 seconds, "00" indication appears on the
2. Press the timer cancel button repeatedly until a long beep sounds.
„ The code indication changes in the sequence shown below.
Note:
1. A short beep "pi" and two consecutive beeps "pi pi" indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
Service Diagnosis
temperature display section.
< ARC433 Series >
No.
Code
00
1
U4
2
L5
3
E6
4
H6
5
H0
6
A6
7
E7
8
U0
9
F3
10
A5
11
remote control is left untouched for 60 seconds, it also returns to the normal mode.
TIMER CANCEL button
No.
Code
F6
12
C7
13
A3
14
H8
15
H9
16
C9
17
C4
18
C5
19
J3
20
J6
21
E5
22
Service Check Function
(R11949)
No.
Code
A1
23
E1
24
UA
25
UH
26
P4
27
L3
28
L4
29
H7
30
U2
31
EA
32
AH
33
100