Trial Operation

1. Trial Operation
Outline
1. Measure the supply voltage and make sure that it falls in the specified range.
2. Trial operation should be carried out in either cooling or heating mode.
3. Carry out the trial operation in accordance with the operation manual to ensure that all
„ The air conditioner requires a small amount of power in its standby mode. If the system is
„ If the circuit breaker trips to shut off the power to the air conditioner, the system backs up the
In cooling mode, select the lowest programmable temperature; in heating mode, select the
highest programmable temperature.
„ Trial operation may be disabled in either mode depending on the room temperature.
„ After trial operation is complete, set the temperature to a normal level.
„ For protection, the system does not start for 3 minutes after it is turned off.
Detail
ARC452 Series
(1) Press the ON / OFF button to turn on the system.
(2) Press the both of TEMP buttons and the MODE button at the same time.
(3) Press the MODE button twice.
(4) Press the MODE button and select operation mode.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a
287
functions and parts, such as louver movement, are working properly.
not to be used for some time after installation, shut off the circuit breaker to eliminate
unnecessary power consumption.
operation mode. The system then restarts operation with the previous mode when the circuit
breaker is restored.
(26°C to 28°C in cooling mode, 20°C to 24°C in heating mode)
("T" appears on the display to indicate that trial operation is selected.)
trial operation, press the ON / OFF button.
(2) (3) (4)
SiENBE04-808_A
(3)
(2)
(2)
(1) (5)
(R9675)
Trial Operation and Field Settings