REMOVAL
PROCEDURE
S E R V I C E
2.0/2.2/2.5/2.8/3.5/3.6/4.1/4.2/4.6/
5.0 kW Class
7000/9000/12000/15000 Btu/h Class
Indoor Unit
Inverter
Wall Mounted Type
Si041252EE
M A N U A L

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTKS09JV2S

  • Page 1 Si041252EE REMOVAL PROCEDURE S E R V I C E M A N U A L 2.0/2.2/2.5/2.8/3.5/3.6/4.1/4.2/4.6/ 5.0 kW Class 7000/9000/12000/15000 Btu/h Class Indoor Unit Inverter Wall Mounted Type...
  • Page 2 Service Manual Removal Procedure Indoor Unit Cooling Only Heat Pump FTKS09JV2S ATXS20G2V1B FTKS12JV2S ATXS25G2V1B ATXS35G2V1B FTKS20KVMA ATXS42G2V1B FTKS25KVMA ATXS50G2V1B FTKS35KVMA CTXS07LVJU FTKS22MVLT FTXS09LVJU FTKS28MVLT FTXS12LVJU FTKS36MVLT FTXS20KVMA FTKM09NV2S FTXS25KVMA FTKM12NV2S FTXS35KVMA FTKM15NV2S FTXS22MVLT FTKM25NVM FTXS28MVLT FTKM35NVM FTXS36MVLT FTKM42NVM FTXM22NVLT FTKM20PVMA...
  • Page 3: Table Of Contents

    Si041252EE Table of Contents 1. Air Filters ....................2 2. Front Panel....................3 3. Front Grille ....................4 4. Horizontal Blades ..................5 5. Vertical Blade ASSYs................6 6. Electrical Box ..................8 7. PCBs .....................10 8. Swing Motors ..................13 9. Indoor Heat Exchanger .................16 10.Fan Motor....................18 Note: The illustrations may be slightly different depending on the model.
  • Page 4: Air Filters

    Air Filters Si041252EE 1. Air Filters Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the air filters. The air filter is not marked Front panel Air filter for difference between the Open the front panel.
  • Page 5: Front Panel

    Si041252EE Front Panel 2. Front Panel Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Open the front panel Front panel over the position where it stops. (R7906) Slide the front panel to When reassembling the front...
  • Page 6: Front Grille

    Front Grille Si041252EE 3. Front Grille Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the screw and Service cover remove the service cover. (R7911) Remove the 2 screws. The convex marks (...) on Hook the front grille indicate the...
  • Page 7: Horizontal Blades

    Si041252EE Horizontal Blades 4. Horizontal Blades Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Release the center The size of the blades is Horizontal blade (large) shaft while bending the different.
  • Page 8: Vertical Blade Assys

    Vertical Blade ASSYs Si041252EE 5. Vertical Blade ASSYs Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the fan guards. Some models have no fan guard.
  • Page 9 Si041252EE Vertical Blade ASSYs Step Procedure Points Unfasten the 3 hooks at the upper 3 positions by pressing them with a flat screwdriver. (R13094) Remove the vertical Each vertical blade ASSY Hook blade ASSY. has 5 fins. It is impossible to replace only one fin.
  • Page 10: Electrical Box

    Electrical Box Si041252EE 6. Electrical Box Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the screw and For U.S. models Electrical box remove the wire fixture. When reassembling, make sure that the connecting wire Remove the 4 screws...
  • Page 11 Si041252EE Electrical Box Step Procedure Points Pull out the indoor heat The position of the indoor Indoor heat exchanger thermistor exchanger thermistor. heat exchanger thermistor varies by model. Be careful not to lose the clip of the thermistor. Clip (R7937) (R11268) Remove the screw and detach the earth /...
  • Page 12: Pcbs

    PCBs Si041252EE 7. PCBs Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the shield plate. The figure shows the parts of the electrical Shield plate box.
  • Page 13 Si041252EE PCBs Step Procedure Points Remove the signal receiver unit. Signal receiver unit (R8088) 3. Remove the [S26] INTELLIGENT EYE sensor PCB. Unfasten the 3 hooks INTELLIGENT EYE and remove the sensor PCB INTELLIGENT EYE Hook sensor PCB. Disconnect the connector [S26].
  • Page 14 PCBs Si041252EE Step Procedure Points 5. Remove the display PCB. The display PCB faces the rear side of the signal Unfasten the 4 hooks receiver unit. and remove the display PCB. Display Hook (R21140) Disconnect the [S49]: control PCB connector [S49]. [S49] (R21141) 6.
  • Page 15: Swing Motors

    Si041252EE Swing Motors 8. Swing Motors Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Caution When reassembling, do not confuse the installing order of the 2 motors for horizontal blades and the colors of the connectors.
  • Page 16 Swing Motors Si041252EE Step Procedure Points Remove the swing motor unit. Interlock shaft Swing motor unit (R21144) Detach the interlock Interlock shaft shaft from the swing motor with a flat screwdriver. (R8127) Remove the vertical Vertical blade interlock blade interlock with a flat screwdriver.
  • Page 17 Si041252EE Swing Motors Step Procedure Points Disconnect the Connector: green connector. (R10334) 2. Remove the swing motors Reassembling order for horizontal blades. (1) Set the swing motor for the upper blade first. Remove the screw and (connector: white) remove the swing (2) Then, set the swing motor motors for horizontal Connector for...
  • Page 18: Indoor Heat Exchanger

    Indoor Heat Exchanger Si041252EE 9. Indoor Heat Exchanger Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. In pump-down work, be sure to stop the compressor before disconnecting the refrigerant pipe. If the refrigerant pipe is disconnected with the compressor operating and the stop valve open, air may be sucked in and may generate an over-pressure in refrigeration cycle, thus resulting in pipe rupture or accidental injury.
  • Page 19 Si041252EE Indoor Heat Exchanger Step Procedure Points Remove the 2 screws on the left side. (R10546) Unfasten the upper hook on the right side with a flat screwdriver. Upper hook (R21146) After unfastening the When reassembling the Indoor heat exchanger lower hook, lift up the indoor heat exchanger, indoor heat exchanger...
  • Page 20: Fan Motor

    Fan Motor Si041252EE 10.Fan Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the 2 screws and remove the right side plate. Right side plate (R21147) Remove the 2 screws When reassembling the fan...
  • Page 21 Revision History Month / Year Version Revised contents 09 / 2012 Si041252 First edition 11 / 2012 Si041252_A Model addition: ATXS20/25/35/42/50G2V1B 04 / 2013 Si041252_B Model addition: FTKS09/12JV2S, FTK(X)S22/28/36MVLT, CTXS07LVJU, FTXS09/12LVJU 06 / 2014 Si041252EC Model addition: FTKM09/12/15NV2S, FTKM25/35/42NVM 12 / 2014 Si041252ED Model addition: FTK(X)M20/25/35/46PVMA 08 / 2015...
  • Page 22 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.