Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
4.8
Removal of Compressor
Procedure
Step
1
Remove the terminal
cover.
2
Disconnect the lead
wires of the
compressor.
3
Unfasten the hooks with
a flat screwdriver to
remove the overload
protector.
259
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Yellow (V)
Terminal cover
(R8195)
Red (U)
Blue
(W)
(R8196)
(R8197)
(R8198)
SiENBE04-808_A
Points
Removal Procedure