Troubleshooting
4.4
Fan Motor (DC Motor) or Related Abnormality
A6
Remote Control
Display
Method of
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation.
Detection
Malfunction
The detected rotation speed does not reach the demanded rotation speed of the target tap, and
Decision
is less than 50% of the maximum fan motor rotation speed.
Conditions
Layer short inside the fan motor winding
Supposed
Breaking of wire inside the fan motor
Causes
Breaking of the fan motor lead wires
Defective capacitor of the fan motor
Defective indoor unit PCB
107
SiENBE04-808_A
Service Diagnosis