Standby Electricity Saving

Outline
20-42 Class Only
This function turns power supply OFF to the outdoor unit and sets the indoor unit into energy-
saving mode, thus reducing the power consumption of the air conditioner.
Detail
For 20/25/35 class models, following procedure is required for turning ON the function.
1. Check that the main power supply is turned OFF. Turn OFF if it has not been turned OFF.
2. Remove the stop valve cover.
3. Disconnect the selective connector for standby electricity saving.
4. Turn ON the main power supply.
Caution
Before connecting or disconnecting the selective connector for standby electricity saving, make
sure that the main power supply is turned OFF.
Trial Operation and Field Settings
Jumper
EXIST
1
CUT
2
The standby electricity saving function is turned OFF
before shipping.
<ARC433 series>
J4
Address
EXIST
CUT
(R12065)
1
2
3
Function OFF
Function ON
Field Settings