Download Print this page

Reactor / Partition Plate - Daikin RXD25DVMV Service Manual

Advertisement

Reactor / Partition Plate

4. Reactor / Partition Plate
Warning
Step
Remove the screw and
1
remove the reactor.
2
Remove the 2 screws.
Lift the partition plate
3
and remove it.
10
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Reactor
(R11879)
Partition plate
(R12273)
Hook
(R13508)
Si001266EA
Points
When reassembling, fit the 2
lower hooks into the bottom
frame.
Removal Procedure

Advertisement

loading

This manual is also suitable for:

Rxd35dvmvRxd25hvmvRxd35hvmv