Cable Specifications; Table 9. Twisted Pair Cabling And Distances - Allied Telesis AT-x230-10GP Installation Manual

Gigabit ethernet switches
Hide thumbs Also See for AT-x230-10GP:
Table of Contents

Advertisement

Cable specifications

AT-x230-10GP, AT-x230-18GP and AT-x230-28GP Switches Installation Guide
Table 9 contains the cable specifications for the twisted pair ports.
T
9. T
ABLE
WISTED PAIR CABLING AND DISTANCES
Speed
Standard TIA/EIA 568-B-compliant
Category 3 or better shielded or
10 Mbps
unshielded cabling with 100 ohm
impedance and a frequency of 16
MHz.
Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
100 Mbps
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.
Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
1000 Mbps
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.
Note
The twisted pair ports on the switch feature auto-MDI when
operating at 10, 100, or 1000 Mbps. A port is configured as MDI or
MDIX when it is connected to an end node. Consequently, you can
use a straight-through twisted pair cable when connecting any type
of network device to a port on the switch.
Type of cable
Maximum
operating
distance
100 m (328 ft)
100 m (328 ft)
100 m (328 ft)
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

At-x230-18gpAt-x230-28gp

Table of Contents