Example - Simrad Robertson AP9 Mk3 Instruction Manual

Autopilot
Table of Contents

Advertisement

Example 3:

AP9 MK3
A P 9 M K II
DISTRIBUTION
DUAL
THR.
ANALOG
INT.
PCB
PCB
NOTE:
The AP9 MK3 autopilot system can provide three galvanic isolated
±10V outputs and be configured as shown in Fig. 1-12.
In this example the Distribution Unit is equipped with one Thruster
Interface board to control the bow thruster, and one Dual Analogue
PCB to control the two aft thrusters.
The Thruster Selector Switch is normally custom-made for each
individual system, and provides the change-over signals for the
thrusters, and the mode for the autopilot.
No Feedback Unit is required!
Thruster Selector Positions:
• MANUAL
• AUTO AFT (Aft Thruster)
• AUTO BOW (Bow Thruster)
FEATURES: First parameter set for synchronized operation of the
20169223D
THRUSTER SELECTOR
A U T O P I L O T
D94
UNIT
MODE
+/-10V
+/-10V
+/-10V
THE D94 CONTAINS ONE THRUSTER INTERFACE
BOARD AND ONE DUAL ANALOG PCB.
Special application, Example 3
aft thrusters.
Second parameter set for the operation of the bow
thruster.
(SPECIAL)
C/O SIGNAL
C/O SIGNAL
C/O SIGNAL
Fig. 1-12
Introduction
BOW
THRUSTER
THRUSTER
ELECTRONICS
THRUSTER
THRUSTER
ELECTRONICS
ELECTRONICS
S
P
AFT THRUSTERS
1-15