5.9
F200-40 Remote Control
This unit is fixed to a mounting bracket, which is secured by four
screws. F200-40 is connected to J5 on the control unit according to
Fig. 5-25
5.10
S9 Steering Lever
Mounting
Refer to Fig. 5-26. For bulkhead mounting, use the 8 bushings
enclosed with the unit. These are placed two and two against each
other and the screws are put through them. Direct contact between S9
and a steel bulkhead is then avoided and corrosion is prevented. The
cover plate can be turned 360 degrees for the most convenient
position of cable outlet. For panel mounting use the two mounting
brackets enclosed with the unit (Fig. 5-27.).
20169223D
11
3
7
F200-40
6
REMOTE
5
CONTROL
8
9
10
Fig. 5-25
F200 Remote Control, connection
Fig. 5-26
S9 Steering Lever, bulkhead mounting
Installation
J/P5
1
2
4
AP9 MK3
5
MAIN
7
CONTROL
UNIT
8
12
13
5-23