Robertson AP9 Mk3 Autopilot
F200-40 and Mode Selection
To allow the F200-40 to control the modes of the AP9 MK3, no links
in connection with NFU-AUTO or FU-AUTO must be present. It is
therefore required to disconnect the links by adding an extra function
to the Mode Selector Switch.
Example:
Complete Mode Selections
By using the following connection, mode selection between F200-
40/NFU/FU/AUTO can be made:
F200-40
(OFF)
If F200-40 is not used, this position can be omitted.
Note !
5-22
MODE SELECTOR
F200-40 as Mode Selector
NFU
FU
AUTO
MODE SELECTOR
Complete mode selection
D9X INTERCONNECTION PCB
TB1
1
2
AUTO
F200-40
NFU
TB3
5
Fig. 5-23
D9X INTERCONNECTION PCB
Fig. 5-24
MODE 1 NFU
MODE 2 FU
COMMON
TB1
1
MODE 1 NFU
2
MODE 2 FU
TB3
5
COMMON
20169223D