NMEA0183 input data:
Calibration start command:.....$PSTOC<cr><lf>
Heading offset adjust: ..............$PSTOK,,,nnn,<cr><lf>
PSTOK and PSTOC are Stowe Dataline proprietary sentences
4.7

Distribution Unit

Dimensions: ............................ See Fig. 4-4.
Protection: ............................... IP22
Weight: .................................... 3,5 kg
Ambient temperature,
Safe distance to magnetic compass: 1.5 m (5')
Mains voltage: ........................ 24V DC +30/–25%
Alarm voltage : ...................... 24V DC ±20 %
Input signals:
Rudder Feedback Unit: ......... 3400 Hz +/-20Hz/degree
Steering Lever
D90 Distribution Unit:
D91 Distribution Unit:
D92 Distribution Unit:
D93 Distribution Unit:
D99 Distribution Unit:
20169223D
storage: .......................... –25 - +70°C
operation:...................... 0 - +55°C
FU :................................. Current signal: 0-1mA (±45°)
NFU : ............................. Switch contacts
Solid state output: ....... Switching low DC (19-40V) single
Solid state output: ....... Switching high DC (110V) single
Solid state output: ....... Switching high/low AC (110-220V)
Analogue output: ........ Two independent channels with
Output: .......................... Switching reversible motor, max. 10A,
Technical Specifications
nnn = offset adjust angle 0 – 360
degree.
channel. 3A.
channel. 1A.
single channel. 1A.
+/-10V or 4-20mA output
24VDC.