Fu9X Follow Up Steering Lever; Fig; Fig . 5-31 Fu9X S; Fig . 5-32 Fu9X - Simrad Robertson AP9 Mk3 Instruction Manual

Autopilot
Table of Contents

Advertisement

Robertson AP9 Mk3 Autopilot
5.11

FU9X Follow up Steering Lever

Mounting
Refer to Fig. 5-31. For bulkhead mounting, use the 8 bushings
enclosed with the unit. These are placed two and two against each
other and the screws are put through them. Direct contact between
FU9X and a steel bulkhead is then avoided and corrosion is
prevented. The cover plate can be turned 360 degrees for the most
convenient position of cable outlet. For panel mounting use the two
mounting brackets enclosed with the unit (Fig. 5-27).
Electrical connection
The FU lever is connected to the D9X Distribution unit according to

Fig. 5-32.

5-26
FU9X Steering Lever, bulkhead mounting
FU9X
1
+15V
GND
2
T.C.
3
FU SIGN.
5
FU9X connection to D9X
Fig. 5-31
D9X DISTRIBUTION UNIT
TB5
4
+15V
1
RTN
3
MODE 2 FU
2
FU SIGN.
Fig. 5-32
INTERCONN.
BOARD
20169223D