NETWORK SETUP

Network Setup allows you to adjust network settings such as Ports, and enable Remote Access.
Remote Client Ports
Time Out Value – When attempting to connect to the recorder, if the connection does not succeed during the timeout period (seconds),
the connection will be terminated (default: 60).
Emergency Port – Connect with the Alarm Monitor software (default port: 2001).
Center Port – Connect with the OpenEye remote software (Remote, RADIUS, the OpenEye app). This port must be specified in the
remote software to connect to the recorder (default port: 2000).
Setup Port – Enable access to recorder setup when using RADIUS. This port is locked to the center port, plus 10. (default port: 2010).
Note Center Port 1025 is not available.
Image Port – Transfers the video to the OpenEye remote software (default port: 2002).
Search Port – Transfers search information to the OpenEye remote software (default port: 2003).
Note If connecting to the recorder through a firewall, the above ports must be open to incoming and outgoing traffic.
Health Check Port – Enable RADIUS to receive information regarding the health of the recorder (default port: 2005).
Audio Port – Enable two-way audio (default port: 3002).
Transport Setup – Use this section to configure the quality and speed of the video sent to remote clients.
Keyboard Control – Enable the recorder to work with a Keyboard Joystick Controller.
Clip Backup – Set the server port for clip backup (default port: 9876).
View IP Address – View the IP address of your recorder for use in remote access applications.
32865AA
View live video
via Internet
Explorer
Enable two-way audio between recorder and Remote Client