LUMINOSITY SETTING
The luminosity setting is composed of the shutter time and the sensor's gain (hereafter gain) settings.
(1) Auto mode
The scanner calculates the shutter time and gain automatically.
(2) Fixed shutter time, Auto gain mode
The shutter time is set with a fixed value, and the gain is calculated automatically.
The shutter time can be set at 0.1ms intervals from 0.1ms – 9.9ms.
The shutter time is set using the commands or the configuration software(QB Setting).
(3) Fixed shutter time, fixed gain mode
The shutter time and gain are set with fixed value.
The gain is set from 0 – 15. 0 is the darkest and bigger value is brighter.
The gain is set with the commands or the configuration software (QB Setting).