(6) Number of digits
This optional field specifies whether or not to transmit the number of digits (2 or 4 bytes) of code data to transmit or disables
the transmission (default). Note that UPC and EAN codes (except GS1-128 (EAN-128)) skip this field.
4 digits (4 byte) transmission
n1 : thousands (0 to 9)
n2 : hundreds (0 to 9)
n3 : tens (0 to 9)
n4 : units (0 to 9)
2 digits (2 byte) transmission
n1 : tens (0 to 9)
n2 : units (0 to 9)
(7) Code data
The data format for each symbology is described below.
QR Code/MicroQR Code/iQR Code
Code data read will be transmitted as is.
Structured Append QR/Structured Append iQR Code
In edit mode and batch edit mode(only Structure Append QR Code): The scanner edits code data read and then transmits it. It
does not transmit the code number, number of splits, or parity.
In non-edit mode: The scanner transmits the code number, the number of splits, parity, and code data read. The code number
and the number of splits are 1 byte each and the parity, 2 bytes in hexadecimal format.
SQRC
Code data read will be transmitted as is. When "Enable transmission of disclosed data only" is selected in "SQRC Encryption
key match", it transmits only non-disclosure data.
X1 X2 ・・・Xn-1 Xn Y1 Y2 ・・・Ym-1 Ym
Xn:Disclosure data
Ym:Non-disclosure data
When "Disclosure data plus non-disclosure data" is selected, the following format applies.
X
X
・・・X
X
Y
1
2
n-1
n
1
When "Transmit only non-disclosure data" is selected, the following format applies.
Y
Y
・・・Y
Y
1
2
m-1
m
PDF417, MicroPDF417, MaxiCode, Data Matrix and Aztec
Code data read will be transmitted as is.
UPC-A
You can select whether or not to transmit the padding character "0," number system character "S," and a check digit to the host.
Disabling the transmission of the number system character "S" automatically disables the transmission of the padding
character "0."
The conversion to the GTIN format is selectable. For the GTIN format conversion, refer to Section 10.7.
When the conversion to the GTIN format is disabled, the following format applies.
0 S X
X
X
X
X
X
X
1
2
3
4
5
6
7
0: Padding character for adjustment of the data length
S: Number system character
UPC-A with add-on
A code ID mark precedes add-on code data under the conditions "Code ID mark: Type 4" and "Code ID mark output mode:
Separating." (For details about the code ID mark, refer to (5) Code ID mark on section 12.4.)
The conversion to the GTIN format is selectable. For the GTIN format conversion, refer to Section 9.5.
When the conversion to the GTIN format is disabled, the following formats apply.
With 2-digit add-on:
0 S X
X
X
X
X
X
X
1
2
3
4
5
6
7
With 5-digit add-on:
0 S X
X
X
X
X
X
X
1
2
3
4
5
6
7
0: Padding character for adjustment of the data length
S: Number system character
X
: Add-on code data
11-15
Y
・・・Y
Y
2
m-1
m
X
X
X
C/D
8
9
10
X
X
X
C/D X
X
8
9
10
11
12
X
X
X
C/D X
X
X
8
9
10
11
12
13
X
X
14
15
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qb30-su

Table of Contents