8.1.2

File entry mode

First, save the verification master data. Up to 50 verification master can be registered. the position of the verification digit can
be designated. the output format for the verification result can be selected, with the position of the verification digit and
verification result output being set using the commands or configuration software(QB Setting). Verification can be made on a
1:n basis for a single master, and on an n:n basis if multiple masters are designated. The maximum number of comparable data
digit is 255.
8.1.2.1

Master data registration

This is set using the commands or configuration software(QB Setting). Commands used for master registration are as follows.
Comman
d
ESTART Starts master data registration
EEND
End master data registration
EF
Master registration command. The registered master(s) is deleted when the power is turned OFF.
EFS
Master registration command. The registered master(s) is retained even when the power is turned OFF.
Master registration command transmission format
"EF"
(Note 1)
Master no.
"EFS"
<Example>
If verification master data (10 digits) "1234567890" is registered to master no. 11:
Master registration command: "EFS11,010,1234567890"
Note 1: Specify a master number between "01" and "50" (2 digits, fixed). If an existing master number is specified,
the original number will be overwritten.
Note 2: Specify the data length of the registered code data in the range "001" to "255" (3 digits, fixed).
The flow for master data registration is as follows.