Page 3
Preface Please READ through these operating instructions carefully. It will enable you to operate your QS20H correctly. After you have finished reading the instructions, keep this manual handy for speedy reference.
Be sure to observe all these safety precautions. Please READ through this manual carefully. It will enable you to use the QS20H correctly. Always keep this manual nearby for speedy reference. Strict observance of these warning and caution indications are a MUST for preventing accidents which could result in bodily injury and substantial property damage.
Page 5
Failure to do so could cause fire or electrical shock. • If you drop the QS20H so as to damage its housing, immediately turn off the power, unplug the AC adapter from the wall socket, and contact your nearest dealer.
Page 6
Moisture or dust will get into the QS20H, resulting in malfunction, fire or electrical shock. • Do not place the QS20H anyplace where it may be subjected to oily smoke or steam, e.g., near a cooking range or humidifier. Doing so could result in a fire or electrical shock.
Page 7
CAUTION • If you will not be using the QS20H for a long time, be sure to unplug the AC adapter from the wall socket for safety. Failure to do so could result in a fire. • Never cover or wrap up the QS20H or AC adapter in a cloth or blanket.
Page 8
Exposure to power surges could result in a damaged QS20H or fire. • When taking care of the QS20H, unplug the AC adapter from the wall socket for safety. Failure to do so could result in an electrical shock.
Page 9
Proper Care of the QS20H To clean the housing, moisten a soft cloth with neutral detergent diluted with water and wring it out thoroughly. Wipe the QS20H with the cloth and then go over it again with a dry cloth.
Content Overviews Preface ........................SAFETY PRECAUTIONS ..................Chapter 1. How to Use ..................Chapter 2. Connecting the QS20H to the PC ............Chapter 3. Parameters and Defaults ..............Chapter 4. QR-coded Parameter Menu ............... Menu control .................... 10 Communications mode ................11 Communications conditions ..............
Reading confirmation LED Illuminates when the QS20H has read the code successfully. Beeper outlet The beeper sounds when the QS20H has read the code successfully Interface connector Via this connector, the QS20H exchanges data with the host computer. DC power jack Connect the AC adapter to this jack.
Page 12
• The illumination LED will turn on when the ambient environment is dark or the target code cannot be read easily. • If the QS20H fails to read due to specular effects or other factors, change the scanning angle of the scanning window or the distance from codes, and try it again.
Page 13
• The QS20H cannot support touch scanning. If you bring the scanning window into contact with a target code, the QS20H cannot read it. • The QS20H can read 2D codes omnidirectionally. Note that the target code including the margin should lie within the scanning range.
Page 14
If you press the trigger switch, the QS20H will become ready to scan. Bringing the scanning window to a 2D code or bar code will cause QS20H to read the code and send it to the connected PC or external equipment automatically.
Page 15
Reading split QR codes (registered as "Structured Append" at AIM) A QR code can be split into a maximum of 16 blocks. The QS20H can read split QR codes. Two reading modes of split QR codes are available—Edit mode and Non-edit mode.
High frequencies may cause the QS20H to malfunction. • Do not set up the QS20H in places where it may be subjected to excessive dust or conductive dust (e.g., carbons or metallic powders). Electrical insulation failures may occur, resulting in a broken scanner.
Chapter 3. Parameters and Defaults The table below lists the parameters and their default values. Note that the defaults given below are values preset when the QS20H leaves the factory. Some of the communications parameters and readable bar code settings may have been modified by dealers according to your needs.
Page 18
Parameter group Parameters Function Factory defaults Reading modes Reading MicroQR Disabled √ Enabled Reading black-and-white Black code on white inverted QR codes background √ White code on black background Edit/Non-edit mode for Edit mode √ split QR codes (“Structured Non-edit mode Append”) Reading PDF417 Disabled...
Make the QS20H ready for scan. Scan the "Start setting" code in the menu control shown on the next page. NOTE: If the "White code on black background" reading is set in the QS20H, scan the black-and-white inverted "Start setting" code.
Page 24
Transmission of code ID mark "Disabled" (default) "Enabled" Transmission of no. of digits "Disabled" (default) "Enabled" "Disabled" (default) "Enabled"...
Chapter 5. Communications The QS20H communicates with the connected PC or external equipment in accordance with the RS-232C. You may set various communications conditions by scanning QR-coded parameters printed in Chapter 4. Communications flow You may select either the non-acknowledge mode or the ACK/NAK mode.
Page 32
ACK/NAK mode Start * You may activate or deactivate Beeps when the QS20H the beeper by using the QR- has read a code.* coded parameter menu given in Chapter 4. Initializes the timer. CTS High? Transfers a single 2 seconds elapsed? character.
If not specified as binary codes, all data will be treated as ASCII codes. Listed below are port settings you can select. If data contains double-byte Japanese Kanji or binary data when the character length is set to 7 bits, the QS20H will ignore the MSB.
Page 34
Code ID marks Code ID marks are characters that identify the types of two-dimensional codes and bar codes. You may select whether those ID marks will be transferred, by using the QR-coded parameter menu. Code type Code ID mark QR code Split QR code in non-edit mode ("Structured Append") UPC-A or EAN-13 EAN-8...
Page 35
• QR Code All data read NOTE: If the QS20H reads split QR codes in Non-edit mode, it will transfer not only the read data but the ordinal ID number (a single byte in hex.) assigned to the split code, the number of splits (a single byte in hex.), and parity (double bytes in hex.).
Page 36
• UPC-E where, to X : Data digits C/D: Check digit • CODE39 and ITF (Interleaved 2 of 5) Data read except for the start/stop codes • CODE128 (EAN-128) Data read except for start/stop codes, FNC codes*, and check digit *Note that FNC1 placed in any positions except the 1st and 2nd positions immediately following the start code will be converted into GS (1Dh) and then transmitted.
Appendix. Specifications External dimensions 163 x 72 x 54 mm (6.42 x 2.83 x 2.13 inches) Weight 135 g 230 g (including interface cable) Interface cable length 2 m (78.74 inches) Scanning performance Resolution 0.25 mm (9.84 mils) min. for two-dimensional codes 0.15 mm (5.91 mils) min.
Page 38
CS (CTS) Ready to send Input RS (RTS) Request to send Output Wiring example Shown below is an example of wiring the QS20H up to the PC. QS20H RD 2 2 SD 3 RD SD 3 SG 5 5 SG...
Page 39
Interface circuits Output circuit Input circuit TXD, RTS RXD, CTS RS-232C LEVEL RS-232C LEVEL Voltage polarity Logical value Control level 0 (space) 1 (mark)
Page 41
The purpose of this manual is to provide accurate information in the handling and operating of the QS20H. Please feel free to send your comments regarding any errors or omissions you may have found, or any suggestions you may have for generally improving the manual.