Setting command
Image save
Image save conditions
Image
memory
designation
Setting command
Set scan test
The QB30 switches to Scanning Test with "Test analysis start (=TESTON#nnn)", and then after receiving the following test
commands, returns to normal mode with "Test end (=TESTOFF)".
During the setting mode, the decoder cannot enter the test mode.
nnn represents the test count, with a range of between 001 and 999 times. (However, if nnn=000, test scanning is performed
continuously.)
(Note 1)
The designated items are as follows:
Parameter
Item
n
Error correction count/total no.
of codewords
m
Scan result (OK/NG)
l
Code information
p
Number of accumulation
Output type example: When "WR51#00000" specified:
Header [0001/0026] [OK] [MODEL2,V1,ECCM,M3] C [6/10]1234567890 Terminator
Error correction count 1/total no. of codewords 26, Decoding successful,
QR code Model 2, Ver1, Error correction level: M, Master no. 3,
Continuous reading mode, 6th successful decode, Total of 10 decoded images,
Decode data 1234567890
Image Memory Setting Command
Transmitted command
(Change) WR53#n
(Confirmation) RD53
(Change) WR54#n
(Confirmation) RD54
(Change) WR55#nn
no.
(Confirmation) RD55
Scanning Test Setting Commands
Transmitted command
(Change) WR51#nmlpq
(Confirmation) RD51
OK
n=0: Disabled
n
n=1: Enabled
n=2: Clear all image memories
OK
n=0: Saves all acquired images.
n
n=1: Saves all unsuccessful image.
n=2: Saves all successful images.
n=3: Saves first image within trigger.
n=4: Saves last image within trigger.
n=5: Saves all images within trigger.
n=6: Saves first unsuccessful image within
trigger.
n=7: Saves last unsuccessful image within
trigger.
n=8 Save the last image within trigger when
scanning is unsuccessful within trigger
OK
n=00 - 19: Specify the memory address.
nn
n=99: Cyclic
Response
OK
nmlpq (Note 1)
0
1
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
122
Response