8.1.1.2
Master data registration with command
The following chart is the procedure of master data registration with commands.
Note1: Following two types of commands are supported for master registration.
Command
ENT
Master data registration The registered master(s) is deleted when the power is turned OFF.
ENTS
Master data registration The registered master(s) is retained even when the power is turned OFF.
8.1.1.3
Verification digit position designation
This is set using the commands or configuration software.. All digits will be compared if no verification digit position is
designated. Only the designated digit position is compared if a verification digit position is designated, and the verification
master and number of digits (data length) in the scanned code data are ignored.
Example in which verification digit position designation is used.
Verification master data (10 digits) :0034500000
Scanned code data (11 digits)
Verification digit position setting:3rd to 5th digit
verifiedVerification result output:OK
8.1.1.4
Verification result output
This is set using the commands or configuration software.. The verification result output format can be selected from the
following four patterns. "NO MASTER" is output if scanned when the master data is not registered.
Pattern 1
Pattern 2
Pattern 3
Pattern 4
START
Master registration command
transmission
Master code scanning
No
Decode Successful?
Yes
Master registration
END
:12345000000
When Verification Successful
"OK"
"OK"+ <data>
"OK"
"OK"+ <data>
20
Note 1
Details
When Verification Unsuccessful
"NG"
"NG"
"OK"+ <data>
"NG"+ <data>