16.4 Parameter list

Par.
Configuration
No.
options
101
Wash program
Key 1
102
Wash program
Key 2
103
Wash program
Key 3
104
Rinse agent
Dosing quantity
105
Rinse program
Dosing quantity
106
Hardness degree
107
Beep ON/OFF
109
Partial / full de-
salination avail-
able?
110
Hardness litres
per cartridge type
111
Total Operation
time
Indication
112
Total number of
wash cycles
113
Total number of
wash cycles since
last reset
114
Serial number
115
Condition
Remaining car-
tridge capacity
119
Beep ON/OFF
Datei:1_EcoStar545D-M_9662798_Betriebsanleitung_EN_2009-05.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Use as
value
range
Parameters
1 ...50
Parameters
1 ...50
Parameters
1 ...50
Parameters
0.10 ...1.00
Parameters
0.1...20.0
Parameters
0 ...50
Parameters
0/1
Parameters
0,1,2
Parameters
0 ...250
Indication
5 figures
Indication
5 figures
Indication
5 figures
Indication
8 figures
Indication
0 ...100
Parameters
0/1
Update:2009-12-18 MRL
W e reserve the right to change execution and construction!
Unit
Factory
setting
-
2
Allocate the wash program to the
key I
Assignment adjustable
-
3
Allocate the wash program to the
key II
Assignment adjustable
-
7
Assign rinse programme -no. of
the key I+II pressed together;
Assignment adjustable
ml/Liter
0.2
Value can be read from the rinse
water
aid container label (dependant on
water quality)
ml/Liter
2.0
Value can be read from the deter-
water
gent container label (dependant on
water quality)
[°dH]
30
The quantity of soft water available
(°KH)
between two regenerations de-
pends onthe hardness of the wa-
ter.
for partial demineralisation TE too
-
1
Switch on/off acoustic ready mes-
sage
-
0
Partial / full desalination available?
0: NO
1: partial demineralisation (TE)
2: full desalination (VE)
1000 L
120
When the cartridge's capacity is
reached (hardness litres/degree of
hardness), "Replace Cartridge" will
be displayed
(INFO 725) (only in the case of
TE)
h
Operation time
query only
-
Wash cycles/loads,
query only
-
Wash cycles/loads,
re-setting possible
-
Option for calling the serial number
%
Only for partial / full desalination
TE: indication in %
VE: 100 = OK;
0 = replace
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
Note