Parameter List - Meiko FV 28 GiO Operating Instructions Manual

Glasswashing machine
Hide thumbs Also See for FV 28 GiO:
Table of Contents

Advertisement

Operating instructions FV 28 GiO

16.4 Parameter list

Par.
Configuration
No.
options
101
Wash program
Key 1
102
Wash program
Key 2
103
Wash program
Key 3
104
Rinse agent
Dosing quantity
105
Rinse program
Dosing quantity
107
Beep ON/OFF
111
Total Operation
time
Indication
112
Total number of
wash cycles
113
Total number of
wash cycles since
last reset
114
Serial number
119
IR-communication
120
Total number of
wash cycles Indi-
cation
201
Machine type
Datei:1D3A4F9D.doc
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Use as
value
range
Parameters
1 ...50
Parameters
1 ...50
Parameters
1 ...50
Parameters
0.10 ...1.00
Parameters
0.1...20.0
Parameters
0/1
Indication
5 figures
Indication
5 figures
Indication
5 figures
Indication
8 figures
Parameters
0/1
Parameters
0/1
Parameters
101 ...104
W e reserv e the right to change execution and construction!
Unit
Factory
setting
-
3
Allocate the wash program to the
key I
Assignment adjustable
-
11
Allocate the wash program to the
key II
Assignment adjustable
-
13
Assign rinse programme -no. of
the key I+II pressed together;
Assignment adjustable
ml/Liter
0.2
Value can be read from the rinse
water
aid container label (dependant on
water quality)
ml/Liter
2.0
Value can be read from the deter-
water
gent container label (dependant on
water quality)
-
1
Switch on/off acoustic ready mes-
sage
h
Operation time
query only
-
Wash cycles/loads,
query only
-
Wash cycles/loads,
re-setting possible
-
Option for calling the serial number
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION! All changes to ser-
vice parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, otherwise
factory settings will not be loaded.
Without power supply reset, the
information 123 will be displayed.
-
101
101: EcoStar E/A1 (with FA, EW)
102: EcoStar E/A2 (minimal)
103: EcoStar E/A1 (with new dos-
ing technology / ADT)
104: EcoStar with TL or A0
Attention! Only assignment list and
machine sequences change – no
parameters
Note
28/38
9671086

Advertisement

Table of Contents
loading