Operating conditions

It is taken for granted that the planning of the system, as well as installation, setting in
operation and maintenance works are executed by sufficiently instructed staff and that
these works are checked by responsible specialists. The indications on the name plate of
the machine must correspond to the technical sheet and the local connection conditions.
Conditions to be provided by the customer:
Frost free storage and installation area
Electrical connection in accordance with the technical sheet
Fresh water connection in accordance with the technical sheet
Waste water connection in accordance with the technical sheet
Anti-slip floor coverings should be provided around the washing appliance.
6.3.1 Requirements for the installation area
Ensure that the storage and installation area is permanently frost free.
The machine is only frost-resistant in the state it is delivered or when provided with
special features (option: frost drainage). If the appliance is installed in an area where
the surrounding temperatures are below freezing point, the water freezing inside can
damage the internal water components such as pump, solenoid valve, boiler, etc.
6.4

Requirements for the electrical connection

Work on the electrical part of the machine may only be undertaken by specialist per-
sonnel.
The customer must guarantee the following points relating to the connection:
The correct voltage and type of current must be available
Mains supply lines must be protected according to regulations and provided with a
main switch.
Appliances must have a fixed connection and equi-potential bonding.
If an unearthed neutral (N) is used with threephase current, the main switch must
have 4-poles (with alternating current 2-poles).
For connection to three-phase current a 5-pole terminal strip (L1, L2, L3, N, PE)
must be used.
Electricity supply without neutral conductor (N): when connecting to three-phase
current, use a 4-pole clamping strip (L1, L2, L3, PE).
Conductor colors: live conductor L1 = black/1, L2 = brown/2, L3 = black/3, neutral
conductor N = blue/4, protective earthing conductor PE = green-yellow.
Protective measures as well as the connection of the equi-potential bonding must be
carried out according to DIN VDE 0100-540 and conform to the local power utilities
regulations.
Do not protect by fuses any additional consumers together with the dishwashing ma-
chine.
All conductor fixing screws must be re-tightened before commissioning the appli-
ance.
The wiring diagram is behind the front panel, resp. front cladding of the appliance.
The enclosed wiring diagram must remain in the appliance.