Parameter List - Meiko UPster U 400 Operating Instructions Manual

Glass and dishwashing machine
Table of Contents

Advertisement

Operating Instructions UPster U 400 / U 500 / U 500S

17.4 Parameter list

Par.
Configuration
no.
options
101
Wash program
Key 1
102
Wash program
Key 2
103
Wash program
Key 3
104
Rinse agent
dosing quantity
105
Detergent
dosing quantity
106
Degree of hard-
ness
107
Beep ON/OFF
109
Partial/full demi-
neralisation
available?
110
Hardness litres
per cartridge type
111
Total operating
time
display
112
Total number of
wash cycles
113
Total number of
wash cycles since
last reset
114
Serial number
115
Condition
remaining
cartridge capacity
119
IR communication
9735077
Use as
Value range Unit
Parameters
1 ... 50
Parameters
1 ... 50
Parameters
1 ... 50
Parameters
0.10 ... 1.00
Parameters
0.1... 20.0
Parameters
0 ... 50
Parameters
0/1
Parameters
0,1,2
Parameters
0 ... 250
Display
5 figures
Display
5 figures
Display
5 figures
Display
8 figures
Display
0 ... 100
Parameters
0/1
Design and construction subject to change without prior notice
Page
Factory
setting
-
5
Allocate the wash program to the
key I;
Assignment adjustable
-
7
Allocate the wash program to the
key II;
Assignment adjustable
-
7
Assign rinse programme -no. of
the key I+II pressed together;
Assignment adjustable
ml/litre
0.2
The value can be read from the
water
rinse aid container label (depends
on the water quality)
ml/litre
2.0
Value can be read from the deter-
water
gent container label (dependant on
water quality)
°dH
30
The quantity of soft water available
(°KH)
between two regenerations de-
pends onthe hardness of the wa-
ter.
for partial demineralisation TE too
-
1
Switch on/off acoustic ready mes-
sage
-
0
Partial/full demineralisation availa-
ble ?
0: no
1: partial demineralisation (TE)
2: full demineralisation (FD)
When the cartridge's capacity is
1000 l
120
reached (hardness litres/degree of
hardness), "Replace Cartridge" will
be displayed
(INFO 725) is displayed (only in
the case of TE)
h
Operating time,
query only
-
Wash cycles/loads,
query only
-
Wash cycles/loads,
resetting possible
-
Option for calling the serial number
%
Only for partial / full demineralisa-
tion:
TE: indication in %
VE: 100 = OK; 0 = replace
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)