16.4 Parameter list

Par.
Configuration
No.
options
101
Wash program
Key 1
102
Wash program
Key 2
103
Wash program
Key 3
104
Rinse agent
Dosing quantity
105
Detergent
Dosing quantity
107
Beep ON/OFF
111
Total Operation
time
Indication
112
Total number of
wash cyclesTotal
number of wash
cycles
113
Total number of
wash cycles since
last reset
114
Serial number
119
Beep ON/OFF
120
Total number of
wash cycles Indi-
cation
201
Machine type
Datei:1_EcoStar430F-MIKE_9702129_Betriebsanleitung_EN_2012-07.docx
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Use as
value
range
Parameter
1 ... 50
Parameter
1 ... 50
Parameter
1 ... 50
Parameter
0.10 ... 1.00
Parameter
0.1... 20.0
Parameters
0/1
Indication
5 figures
Indication
5 figures
Indication
5 figures
Indication
8 figures
Parameter
0/1
Parameter
0/1
Parameter
101 ... 104
Update:
W e reserv e the right to change execution and construction!
Unit
Factory
setting
-
3
Allocate the wash program to the
key I
Assignment adjustable
-
11
Allocate the wash program to the
key II
Assignment adjustable
-
13
Assign rinse programme -no. of
the key I+II pressed together;
Assignment adjustable
ml/Liter
0.2
Value can be read from the rinse
water
aid container label (dependant on
water quality)
ml/Liter
2.0
Value can be read from the deter-
water
gent container label (dependant on
water quality)
-
1
Switch on/off acoustic ready mes-
sage
h
Operation time
query only
-
Wash cycles/loads,
query only
-
Wash cycles/loads,
re-setting possible
-
Option for calling the serial number
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
-
0
Effective only upon power supply
reset ON/OFF
Attention! All changes to service
parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, other-
wise factory settings will not be
loaded.
Without power supply reset, the
information 123 will be displayed.
-
101
101: EcoStar E/A1 (with FA, EW)
102: EcoStar E/A2 (minimal)
103: EcoStar E/A1 (with new dos-
ing technology / ADT)
104: EcoStar with TL or A0
Caution! Only assignment list and
machine sequences change – no
parameter
Note