Lsu Error Rap - Xerox Phaser 4620 Service Manual

Hide thumbs Also See for Phaser 4620:
Table of Contents

Advertisement

06-100-00, 06-200-00 LSU Error RAP

06-100-00 The Laser Unit has failed. The Laser Unit did not reach ready within a defined time.
06-200-00 LSU Hsync Error. The Laser Unit has failed.
BSD-Reference:
WD 8
Initial Actions
Cycle system power.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Cycle system power. The error message is displayed.
Y
N
Perform
SCP 6
Final Actions.
Select
dC330
code 06-100 to test the Laser Unit. The Laser Unit is operational (on/off).
Y
N
Replace the Laser Unit
(REP
6.1), then retest. The Laser Unit is operational.
Y
N
Replace the IP Board
(REP
3.6).
Reassemble and perform
SCP 6
Final Actions.
Reassemble and perform
SCP 6
Final Actions.
Revision - Xerox Internal Use Only
Phaser 4600/4620 Printer Service Manual
WARNING
07-110-00 Paper Empty at Tray 2 RAP
07-110-00 The Tray 2 No Paper indicates the Tray is empty.
BSD-Reference:
WD 3
Initial Actions
1.
Add media to the Tray.
2.
Check the No Paper Sensor Actuator.
3.
Check for obstruction of the Pick mechanism.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Check the Tray 2 No Paper Sensor Actuator. The actuator is undamaged and motion is
good.
Y
N
Repair or replace the Tray 2 No Paper Sensor Actuator.
Select
dC330
code 07-210 to test the sensor. The sensor signal changes (high/low).
Y
N
Replace the Tray 2 No Paper Sensor
changes.
Y
N
Remove the Right Cover
retest. The sensor signal changes.
Y
N
Replace the MCU Board,
Reassemble and perform
Reassemble and perform
SCP 6
Reassemble and perform
SCP 6
Final Actions.
5/2011
2-23
WARNING
(PL 8.15 Item
19), then retest. The sensor signal
(REP
28.2) and reseat CN12 on the MCU Board, then
REP
3.4.
SCP 6
Final Actions.
Final Actions.
Status Indicator RAPS
06-100-00, 06-200-00, 07-110-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 4600

Table of Contents