7510-XXX
Setup and adjustments
Sensor (ATC) setup
Step
1
Warning: Before installing any new developer unit assembles in the machine, record the bar code
number located on the sensor (ATC) for all new developer units being installed.
Example:
Sensor (C ATC) XXX
Sensor (M) ATC XXX
Sensor (Y) ATC XXX
Sensor (K) ATC XXX
2
Using the bar code number recorded from the sensor (ATC) on each of the new developer unit
assemblies in step 1, locate the values for the following settings using the ATC value conversion chart
shown after step 4:
Sensitivity gradient
Sensor output reference
3
Update the following settings using the newly converted values from step 2 for all newly installed
developer units:
Sensitivity gradient
Sensor output reference
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch ATC Sensor Adjust Values
4. Enter new values.
5. Touch Submit.
Warning: This procedure must be done for all new developer unit assemblies being installed or print
quality problems may occur.
4-250
MFP Service Manual
Check
Yes
No