4.5.5 Removing the Ballast Filter Assy./Security Bar/Lower Case

1. Remove the Ballast Filter Assy. from the Lower Case.
2. Remove the Lower Shield Plate from the Lower Case.
3. Remove the two screws (C.B.P-TITE SCREW,2.5X10,F/ZN-3C) that secure the Security
Bar Cover, and remove the Security Bar Cover and the Security Bar from the Lower Case.
4. Remove the two gaskets (5x5L=10) from the Lower Shield Plate.
5. Remove the following parts from the Lower Case.
(a) BS Sheet FIF
Lower Shield Plate
Ballast Filter Assy.
Lower Case
SEIKO EPSON
(a)
Figure 4-71.
4-58
CONFIDENTIAL
Security Bar Cover
Security Bar
Revision:C