EMP-1825/EMP-1815/EMP-1810
Secure the SW cable and the ferrite core of the Control Panel to the Upper
C A U T I O N
Case with heat-resistant tape according to the standard below.
• Red lines: 4.5cm
• Blue lines: attach the ferrite core in the center between the lines.
• Green lines: the same length as the Control Panel.
• Fold the SW Cable outward at 90 degrees between the Wireless LAN socket and
the rib shown in (1), then fold back the cable inward at 180 degrees aligning it
with its right edge as shown in (2).
• Secure the fold with heat resistant tape as shown in (3).
• No caught cables, or floating case is allowed.
• Connect the following connectors.
SEIKO EPSON
±
5mm in between.
SW cable
LAN Socket
Rib
(1)
Connector No.
CN1201
CN1203
CN1204
Figure 4-14.
(2)
Figure 4-15.
Connected to
Lamp Lid Detection SW
Control Panel
Photo Interrupter
4-17
CONFIDENTIAL
Tape
(3)
Revision:C