4.2.19 Removing the Lamp Lid Detection Switch, Lamp Lid Detection
Switch Plate, Plate PS Conduction A, Plate PS Conduction B, RC
Filter, Heatresistant Sheet; A, Heatresistant Sheet; B, and Lower Case
1. Remove the screw (C.B.P-TITE SCREW, 3x10, F/ZB-3C) that secures the Lamp Lid
Detection Switch Plate, and remove the Lamp Lid Detection Switch Plate.
2. Remove the screw (C.P.(S-P1) SCREW, 2.3x10, F/ZN-3C) that secures the Lamp Lid
Detection Switch, and remove the Lamp Lid Detection Switch.
3. Remove the Plate PS Conduction A and Plate PS Conduction B from the Lower Case.
4. Remove the RC Filter from the Lower Case.
5. Remove the Heatresistant Sheet; A and Heatresistant Sheet; B from the Lower Case.
Switch, Lamp Lid Detect
Plate PS Conduction A
Plate PS Conduction B
Heatresistant Sheet; A
SEIKO EPSON
EMP-TW1000
C.B.P-TITE SCREW, 3x10, F/ZB-3C
Lamp Lid Detection Switch Plate
Heatresistant Sheet; B
Figure 4-46.
4-42
Filter, RC
Revision:A