Epson EMP-1825 Service Manual page 110

Hide thumbs Also See for EMP-1825:
Table of Contents

Advertisement

EMP-1825/EMP-1815/EMP-1810
7. Press the [QuickSetup] button once.
• The calibration at the Wide position starts.
• When the calibration has been successfully finished, the image changes to a big "C (rep-
resenting "Center") automatically. [Pause Window 2]
• If the Zoom Ring is not set to the end of the Wide side, the image returns to the "W"
(Pause Window 1) automatically.
• If this calibration has been failed, the [Unsuccessful Termination] window is displayed.
(refer to
[Unsuccessful Termination] window (p.
8. Adjust the Zoom Ring manually to the center position as shown in the figure below.
9. Adjust the focus of the projected image with the Focus Ring.
SEIKO EPSON
Figure 5-4. Pause Window 2
W
T
Figure 5-5. The Center position of the Zoom Ring