Christie CP2220 User Manual page 144

Hide thumbs Also See for CP2220:
Table of Contents

Advertisement

Appendix B: Serial API
Backup (BCK)
Backup configuration, preferences, channel data, user data and ICP files to a file that can later be restored.
SUBCODE
DESCRIPTION OF USE
NONE
Run a backup, argument 1 to start backup, argument 0 does nothing.
STAT
Get the backup status.
EXAMPLES:
(BCK 1) Start a backup. The file is saved to the FTP root.
(BCK+STAT?) Returns the status of the last backup and the location of the resulting file.
Baud Rate (BDR)
Set the baud rate for a serial communications port.
SUBCODE
DESCRIPTION OF USE
PRTA
Set the baud rate on port A. Rates can be 1200, 2400, 9600, 19200, 38400, 57600, or 115200.
EXAMPLES:
(BDR+PRTA6) Set baud rate on port A to 115200 bits per second
(BDR+PRTA?) Get baud rate (BDR+PRTA!006 "115200)
Channel (CHA)
Select Channel configuration to use. Channel range is 101 to 164. Channel configuration sets the input routing and image pro-
cessing options for input signals.
SUBCODE
DESCRIPTION OF USE
NONE
Select Channel. Valid range 101 - 164
EXAMPLES:
(CHA?) Get current active channel
(CHA 108) Set channel 108 as active channel
Channel Icon (CHI)
Set icon file name and path for the specified channel. This selects the icon to be displayed on the Web UI for the channel button.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select icon for the current channel.
EXAMPLES:
(CHI+C108 "/etc/data/icons/ch108.ico") Use ch 108.ico for channel 108.
(CHI+C108 ?) Get icon file name and path for channel 108.
(CHI?L) List all available channel icon entries.
B-2
CP2220 User Manual
020-100420-08 Rev.1 (5-2014)

Advertisement

Table of Contents
loading

Table of Contents