4. Type the cfgdevice command:
a. To check the status of current drives:
XSCF> cfgdevice -l
b. To detach a drive:
XSCF> cfgdevice -f -c detach -p port_no
where port_no is the port number in the specified domain where the device is to
be detached. port_no is specified in the format: IOU number-PCI slot number.
5. Restart the volume management daemon (vold) if necessary:
# /etc/init.d/volmgt start

Related Information

For additional information on this chapter's topics, see:
Resource
man pages
Solaris OS documentation collection
SPARC Enterprise
M3000/M4000/M5000/M8000/M9000
Servers XSCF User's Guide
SPARC Enterprise
M4000/M5000/M8000/M9000 Dynamic
Reconfiguration (DR) User's Guide
Service Manual
70
SPARC Enterprise Mx000 Servers Administration Guide • August 2009
Information
setupfru(8), showfru(8), setdcl(8), showdcl(8), addboard(8),
moveboard(8), deleteboard(8), showboards(8), xntpd(1M),
showdevices(8), showconsolepath(8), console(8),
sendbreak(8), poweron(8), poweroff(8), reset(8), cfgdevice(8),
cfgadm(1M), setdomainmode(8)
Solaris OS installation; NTP; domains; backup operations