Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
Remove the heater and limit switch from
the unit (see page 4-9 for the procedure).
4.
Lower the control chassis so you can
access the fan motor wires (perform steps
3, 6, and 7 on page 4-2).
5.
Disconnect the black and red fan motor
wires from mode switch terminals H and L.
REMOVING THE FAN MOTOR
Mode
Switch
6.
Disconnect the brown and yellow fan mo-
tor wires from the capacitor terminals.
7.
Pull the ends of the four fan motor wires
through the chassis hole and remove them
from the plastic wire clamp.
Wire Clamp
Chassis Hole
BK
RD
(Fan Mtr)
(Fan Mtr)
H
L
L1
6
COM
L2
9
2
8
7
4
3
4-10
BR Fan Mtr
(Green Ring)
YL Fan Mtr
(Black Ring)
5
1