REMOVING THE CONDENSATE VALVE BELLOWS

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug air conditioner or disconnect power.
2.
Remove the unit from the wall sleeve (see
pages 2-10 and 2-11 for the procedure).
3.
Remove the two hex-head screws from
each of the condenser fan shroud mount-
ing brackets and remove the brackets.
4.
Remove the remaining three hex-head
screws from the condenser shroud (1 bot-
tom and 2 side screws).
Condenser
Fan Shroud
Shroud Brackets &
Screws (2 each)
Side Screw (1 of 2)
Bottom Screw
5.
Tilt the top of the condenser fan shroud
forward and pull the left end away from the
condenser just far enough to access the
condensate valve bellows.
Left Side View
Remove Nut
Condensate Valve Bellows
6.
Remove the left 5/16" nylon mounting nut
on the condensate valve bellows, and
loosen the right nut approximately half
way on the chassis pan stud.
4-13
Condenser Fan Shroud
Loosen Nut