C01-07 Reset Count - ISHIDA BC-4000 Service Manual

Hide thumbs Also See for BC-4000:
Table of Contents

Advertisement

3.2.7

C01-07 Reset Count

The number of automatic reset counts is recorded in case of Error "40" occurrence.
Before resetting the number in case particular problems occur, ensure to confirm the record.
Operation
Press the [ ] key repeatedly until C01-07 menu appears.
3.2.7.1
C01-07-00 Number of Reset Times
Operation
1.
Press the [ENTER] key to enter C01-07-00 menu.
The number of reset times is displayed.
2.
To clear the record, press the [ZERO] key twice.
Otherwise, press the [END] key. The screen will return to C01-01 menu.
3.2.7.2
Returning to C01
Operation
Press the [END] key to return to C01-01 menu.
BC-4000 Service Manual No. 085-6693-02
7. RESET COUNT
C01-07
CLEAR? YES = (ZERO+ZERO)
C01-07-00
1. A/D CHECK
C01-01
Chapter 3 TEST MODE
[ENTER]
0000
[ENTER]
3-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents