Troubleshooting - ISHIDA BC-4000 Service Manual

Hide thumbs Also See for BC-4000:
Table of Contents

Advertisement

Chapter 5 ERROR LIST & TROUBLESHOOTING
5.2
TROUBLE SHOOTING
Phenomenon
Power is not supplied.
Test Mode is entered
directly after the power
has been turned OFF.
Machine does not stop
operation after "TEST" is
displayed.
Weight error occurred.
A specific program
cannot be displayed.
A key doesn't work.
Registration data has
changed.
Display disappears all
while operating.
5-2
Cause
1. Power supply plug has
loosened.
2. The fuse has blown out.
3. Main board is defective.
4. Power supply unit is defective.
5. Power switch is defective.
1. Main board is defective.
2. Key sheet is defective.
1. Load cell is defective.
2. External vibration
3. A/D board is defective.
4. Main board is defective.
5. Power supply unit is defective.
1. Limit stopper screw hits
something.
2. There is a foreign object under
the load cell.
3. A/D board is defective.
4. Load cell is defective.
5. Main board is defective.
1. Machine connection error
2. Main board is defective.
3. Display board is defective.
1. Key sheet is defective.
2. Machine connection error
1. Battery is defective.
2. Main board is defective.
3. Influence of external noise
1. Power-supply voltage fluctuation
2. Power supply unit is defective.
3. Display board is defective.
4. Main board is defective.
Measures
1. Insert the plug again.
2. Replace the fuse.
3. Check the main board, and
replace it.
4. Check the power supply unit,
and replace it.
5. Check the power switch, and
replace it.
1. Check the main board, and
replace it.
2. Check the key sheet, and
replace it.
1. Adjust the load cell, and replace
it
2. Change the installation to a
vibration-free place.
3. Check the A/D board, and
replace it.
4. Check the main board, and
replace it.
5. Check the power supply unit,
and replace it.
1. Adjust the limit stopper screws.
2. Remove the foreign body.
3. Replace the A/D board.
4. Adjust the load cell, and replace
it.
5. Check the main board, and
replace it.
1. Check the machine connection.
2. Check the main board, and
replace it.
3. Check the display board, and
replace it.
1. Check the key sheet, and
replace it.
2. Check the machine connection.
1. Replace with a new battery.
2. Check the main board, and
replace it.
3. Change the installation to a
noise-free place.
1. Confirm the power-supply
voltage.
2. Confirm the power supply unit,
and replace it.
BC-4000 Service Manual No. 085-6693-02

Hide quick links:

Advertisement

Table of Contents
loading