4. Select the desured unit number using the [ ] or [ ] key.
or
or
5. Key in the print position data (axis value) in 0.1mm units and press the [ENTER] key.
Note: Print position data cannot be changed for standard format #1 through #4.
6. Press the [END] key to return to the B01-02-01 menu.
2.2.2.3 B01-02-03 Default PLU Number
Operation
1. Press the [ ] key twice to enter 01-02-03 menu.
2. Key in the desired PLU number and press the [ENTER] key.
Example: PLU number "2"
3. Press the [PRINT] key to issue a test label to confirm print position for eack print unit.
2.2.2.4
Returning to B01-02-01
Operation
Press the [END] key to return to B01-02-01 menu.
BC-4000 Service Manual No. 085-6693-02
0:Y AXIS POSITION
b01-02-02 1n31
0:X AXIS POSITION
b01-02-02 0n01
FORMAT No. + [PLU]
b01-02-01 FORMAT No
DEFAULT PLU
b01-02-03 PLU
DEFAULT PLU
b01-02-03 PLU
FORMAT No. + [PLU]
b01-02-01 FORMAT No
Chapter 2 SETUP MODE
(0055)
0
(0019)
0
(30)
30
[ENTER]
00000001
[ENTER]
00000002
(30)
30
2-9