C03 Thermal Head; C03-01 Thermal Head Resistance; C03-02 Print Usage Distance - ISHIDA BC-4000 Service Manual

Hide thumbs Also See for BC-4000:
Table of Contents

Advertisement

Chapter 3 TEST MODE
3.4

C03 THERMAL HEAD

Operation
Press the [ ] key repeatedly until C03 menu appears, or key in "3" and press the [ ] key to enter C03
menu directly.
3.4.1

C03-01 Thermal Head Resistance

Operation
1.
Press the [ENTER] key to enter C03-01 menu.
The thermal head resistance can be set.
Note: The resistance must be set after the thermal head is replaced.
2. Press the [COPY] key to read the ID from the thermal head and set it automatically, or key in the
resistance described on the head and press the [ENTER] key to save it in E2ROM.
or
3.4.2

C03-02 Print Usage Distance

Operation
1.
Press the [ ] key to enter C03-02 menu.
Total print distance of the thermal head can be confirmed.
It is displayed in 100m (0.1Km) units and stored.
2.
To reset the distance, key in the password "495344" and press the [SIZE] key.
3.
Key in the desired usage distance and press the [ENTER] key.
3-10
3 PRINT HEAD
C03
RESISTANCE
C03-01
PRINT USAGE
C03-02
[ENTER]
(960)
( 0.0 km)
BC-4000 Service Manual No. 085-6693-02