■ [EXT KEYPAD] jack
The circuit is used to output memory content in 8 chan-
nel memories. You can output desired memory content
such as CW Memory keyer, Voice memory, RTTY/PSK
Memory to be transmitted. Push a switch to send the
memory information. Hold down the switch for 1 sec-
ond to repeatedly send the memory information.
When you connect the external keypad, turn ON the
following items in the Other set mode.
(SET [F-7] > OTHERS[F-5])
• External Keypad (Voice)
• External Keypad (Keyer)
• External Keypad (RTTY)
• External Keypad (PSK)
Mute switch: Mutes both transmission and reception
when the switch is turned ON.
■ [REF I/O] connector
This connector outputs or inputs a 10 MHz reference
signal.
• Input/Output impedance: 50 Ω
• Output level:
• Required input level:
• Output signal stability:
If you use an external reference signal, set
to "IN" with the "REF IN/OUT" item in the
ACC set mode.
You can adjust the internal Reference Signal frequen-
cy with "REF Adjust" in the ACC set mode.
(SET [F-7] > ACC [F-2] > REF Adjust)
■ [X-VERTER] connector
You can connect your transverter unit
through the connector.
• Input/output impedance:
50 Ω
• Output level: Approximately –20 dBm or more
You can change the transverter function with [OTHER
SET] on the [Transverter Function] screen.
You can also adjust the offset frequency with [Trans-
verter Offset] on the [OTHER SET] screen.
(SET [F-7] > OTHERS [F-5] > Transverter Offset)
(p. 15-16)
Approximately –10 dBm
Approximately –10 dBm
±0.05 ppm (0 ~ +50°C)
S5
S6
S7
S8
Mute switch
■ [RELAY] jack
Goes to ground when transmitting to con-
trol an external non-Icom linear amplifier.
You can select either mechanical relay or
semi-conductor MOS-FET control.
Specifications
• Mechanical relay (Reed Relay):
16 V DC/Less than 0.5 A
• MOS-FET:
Less than 250 V/ Less than 250 mA
You can change the control with the "SEND Relay
Type" item in the ACC set mode.
(SET [F-7] > ACC [F-2] > SEND Relay Type)
When the SEND terminal controls the inductive load
(such as a relay), a counter-electromotive force can
cause the transceiver's malfunction or damage. To pre-
vent this, we recommend adding a switching diode,
such as an "1SS133," on the load side of the circuit to
the counter-electromotive force.
[Example]
Switching diode
ACC 1/2
sockets
e SEND
u 15 V
20-4
B
L
1.5kø
1.5kø
± 5%
± 5%
S1
1.5kø
1.5kø
± 5%
± 5%
S2
2.2kø
2.2kø
± 5%
± 5%
S3
4.7kø
4.7kø
± 5%
± 5%
S4
USER BOX
External Keypad
L
To a non-Icom
linear amplifier
Relay
L